Products Description
API 5L X70 PSL2 LSAW pipe is a high-strength, large-diameter line pipe manufactured by longitudinally forming steel plate into a cylinder and welding the seam with double-sided submerged arc welding. The designation "X70" corresponds to ISO grade L485, with a minimum yield strength of 485 MPa (70,300 psi) and a minimum tensile strength of 570 MPa (82,700 psi). PSL2 (Product Specification Level 2) imposes mandatory Charpy V-notch impact testing, 100% ultrasonic inspection of the weld seam, tighter chemistry limits, and defined maximum strength ceilings - requirements that are not present under PSL1.
In commercial practice, X70 is a PSL2-only grade for any application involving high design pressure, large diameter, or long-distance transmission. LSAW is the preferred manufacturing route for X70 above approximately 16 inches because the plate-based forming process delivers more consistent microstructure and toughness than spiral welding at equivalent wall thickness.
This data sheet covers the standard LSAW configuration for export supply, with 3LPE and FBE coating options and delivery condition M (thermomechanically rolled) as the default for large-diameter transmission service.
| OD (inch) | OD (mm) | Common WT Range (mm) | Typical Export Coating | Typical Length | Primary Market |
| 16″ | 406.4 | 8 – 16 | 3LPE / FBE | 12 m | Medium-diameter gas lines |
| 20″ | 508 | 8 – 18 | 3LPE | 12 m | Gas gathering & transmission |
| 24″ | 609.6 | 9.5 – 20 | 3LPE | 12 m | Transmission laterals |
| 30″ | 762 | 10 – 22 | 3LPE | 12 m | Trunk lines |
| 36″ | 914.4 | 12 – 25 | 3LPE | 12 m | High-volume trunk line export |
| 42″ | 1066.8 | 12 – 28 | 3LPE | 12 m | High-volume trunk line export |
| 48″ | 1219.2 | 14 – 32 | 3LPE / FBE | 12 m | High-volume trunk line export |
| 56″ | 1422.4 | 16 – 38 | 3LPE | 12 m | Large-diameter trunk lines |


✅ Strict API 5L PSL2 quality control, full traceability from heat number to pipe piece
✅ Double-sided SAW, 100% RT / UT weld inspection
✅ High yield strength, excellent low-temperature impact resistance
✅ Optional anti-corrosion: 3LPE, FBE, Dual FBE, 3PP, internal epoxy
✅ Custom end bevel, pup joint, bending, hydrostatic test ✅ Suitable for sour service (HIC / SSCC test available)
✅ Length: single random, double random, fixed length 6m / 12m / 18m
Technical Specifications
1.Chemical Composition -X70 PSL2, Delivery Condition M (LSAW):
| Element | C | Mn | P | S | Nb+V+Ti | Cu | Ni | Cr | Mo |
|---|---|---|---|---|---|---|---|---|---|
| Limit | 0.22 | 1.60 | 0.025 | 0.015 | ≤0.15 | 0.50 | 0.50 | 0.50 | 0.15 |
2.Mechanical Properties :
| Property | Requirement | Test Standard |
| Minimum yield strength (SMYS) | 485 MPa (70,300 psi) | ASTM A370 / API 5L |
| Maximum yield strength | 635 MPa (92,100 psi) | PSL2 ceiling |
| Minimum tensile strength (SMTS) | 570 MPa (82,700 psi) | |
| Maximum tensile strength | 760 MPa | PSL2 ceiling |
| Yield-to-tensile ratio (Y/T) | ≤ 0.93 | Mandatory PSL2 |
| Charpy V-notch impact | 27 J minimum at 0 °C (project-specific temperatures available: −10 °C, −20 °C, −46 °C) | ASTM A370 |
| Elongation | Per API 5L formula, minimum 21% typical |
3.Dimensional Range & Tolerances:
| Parameter | Standard Range | Notes |
| Outside diameter (OD) | 16″ – 56″ (406.4 – 1,422.4 mm) | Up to 60″ / 64″ subject to mill capability |
| Wall thickness (WT) | 8 – 50 mm | 14 – 20 mm most common for 36″–48″ gas transmission |
| Length | 5.8 – 12.3 m (random) or project-specific | Up to 18 m available |
| OD tolerance | ±0.5% (pipe body, D > 508 mm); ±0.75% general | Per API 5L |
| Wall tolerance | −12.5% / +15% (pipe body); tighter on request | Weld zone tolerances tighter |
| Out-of-roundness | ≤ 1.0% D standard; ≤ 0.5% D for expanded pipe ends (PSL2) | |
| Straightness | ≤ 1.5 mm per meter |
4.Manufacturing & Inspection Requirements (PSL2):
| Requirement | PSL2 Mandatory Specification |
| Forming | UOE (U-press → O-press → Expand) or JCOE (J → C → O → Expand) |
| Welding | Double-sided submerged arc welding (inner + outer bead) |
| Weld inspection | 100% ultrasonic testing (UT) of weld seam, mandatory |
| Hydrostatic test | Each pipe, 1.5× design pressure, chart recorded |
| Charpy impact | Mandatory, heat-lot frequency |
| Dimensional inspection | 100% end dimensional check |
| Traceability | Full heat number traceability per MSS SP-25 |
| Mill certificate | EN 10204 3.1 standard; 3.2 (third-party witnessed) strongly recommended for X70 LSAW export orders |


Anti-Corrosion Coating Systems
1.3LPE (Three-Layer Polyethylene):
3LPE is the dominant external coating for buried, large-diameter transmission pipelines. It combines a corrosion barrier, a bonding layer, and a mechanical protection layer into a single system.
| Layer | Function | Typical Thickness |
| Layer 1: Fusion-bonded epoxy (FBE) primer | Corrosion barrier; chemical bond to blast-cleaned steel | ≥ 80 μm minimum; 100 – 150 μm typical |
| Layer 2: Copolymer adhesive | Compatibilizing tie-layer between epoxy and PE | Per coating class |
| Layer 3: Extruded polyethylene topcoat | Mechanical protection: impact, abrasion, soil stress | Total system: 1.8 – 3.7 mm, class-dependent |
Governing standards: ISO 21809-1 (primary international) and DIN 30670 (widely referenced German standard). Specifying "3LPE" alone leaves the coating class undefined - the standard and class together determine actual layer thickness and performance requirements, and both should appear on the purchase order.
Typical 3LPE system for X70 LSAW: FBE primer 100–150 μm + adhesive + PE topcoat to total 2.5–3.7 mm for standard buried service (class-dependent).
2. FBE (Fusion Bonded Epoxy):
Single-layer FBE is used where a thinner, high-performance corrosion coating is preferred - typically for internally coated pipe, pipe that will receive a subsequent concrete weight coating, or applications where polyethylene is not suitable.
| Parameter | Specification |
| Standard | CSA Z245.20 / ISO 21809-2 / project-specific |
| FBE thickness | ≥ 80 μm minimum; 100 – 150 μm conventional; up to 300–500 μm for high-build FBE |
| Application | Blast-cleaned steel surface, electrostatic spray, cured by induction or convection |
| Primary function | Corrosion barrier; excellent chemical resistance and bonding strength |
FBE as the primer in 3LPE vs standalone FBE: In 3LPE, the FBE layer is the corrosion barrier and the PE is the mechanical shield. In standalone FBE, the epoxy layer must provide both functions, so thickness and adhesion requirements are higher. For X70 LSAW export orders, both configurations are available; the choice depends on installation method, soil conditions, and whether concrete weight coating will be applied.
3. Coating Selection Guidance:
| Service Condition | Recommended Coating |
| Buried onshore transmission, standard soil | 3LPE, ISO 21809-1 / DIN 30670 |
| Concrete weight-coated subsea or swamp | FBE (thin, compatible with concrete) |
| Internal corrosion protection | Internal FBE or liquid epoxy (NSF 61 available) |
| High mechanical stress / rocky backfill | 3LPE with increased topcoat thickness |
| Sour service or high-temperature > 60 °C | FBE or 3LPP (polypropylene) - confirm with coating standard |
Applications
| Sector | Typical Application | Why X70 LSAW PSL2 |
| Long-distance gas transmission | Cross-country trunk lines, 24″–56″ OD | High strength enables wall thickness reduction vs X65; LSAW delivers large diameter with consistent toughness |
| Oil transmission | Crude oil and refined product pipelines | PSL2 toughness and 100% UT support high-pressure operation |
| Offshore pipelines & risers | Export lines, infield flowlines | PSL2 mandatory for critical service; LSAW wall thickness capability to 50 mm |
| Water transmission | High-pressure water mains, cooling water lines | 3LPE or FBE provides long-term corrosion protection |
| Structural / piling | Port foundations, bridge piers, monopiles | Large-diameter LSAW dimensional stability; coating optional |
Note on sour service: X70 can be used in mild sour service with ultra-low sulphur (≤ 0.002%) and calcium treatment for inclusion shape control, but the qualification burden is higher than for X65. For H₂S partial pressure > 0.05 psia (0.34 kPa), X65 PSL2 is the default recommendation unless X70 is specifically justified by pressure design and the construction spread is X70-WPS qualified.
FAQ
Q1: What is the difference between PSL1 and PSL2 for X70 LSAW pipe?
PSL2 imposes mandatory Charpy V-notch impact testing (27 J minimum at 0 °C), 100% ultrasonic testing of the weld seam, stricter chemical composition limits (CEIIWIIW ≤ 0.43, Pcm ≤ 0.25), and defined maximum yield and tensile strength ceilings (635 MPa / 760 MPa). PSL1 does not mandate impact testing, does not require 100% weld UT, and has wider chemistry tolerances. In commercial practice, X70 is exclusively ordered as PSL2 - any PSL1 X70 offer for a high-pressure transmission project represents a grade downgrade, not a cost saving.
Q2: Why is LSAW used for X70 instead of seamless or ERW?
Above approximately 16 inches OD, LSAW is the manufacturing method of choice for X70. Seamless X70 above 16 inches requires large-diameter piercing mills that are less widely available, and the dimensional tolerances and toughness consistency achievable in large-diameter seamless are no better than LSAW - often worse, because plate rolling reduction can be higher. ERW is generally limited to smaller diameters. LSAW plate-based forming allows tighter control of chemistry, rolling reduction, and cooling rate, producing a more consistent microstructure for high-pressure X70 service.
Q3: Should I specify delivery condition M or Q?
For LSAW large-diameter transmission pipe, specify M (thermomechanically rolled). X70M has a carbon ceiling of 0.12% versus 0.18% for X70Q. The lower carbon produces better heat-affected zone toughness and requires less preheat during field welding. X70Q is used for seamless small-bore pipe where thermomechanical rolling is not practical. A purchase order that does not specify delivery condition M may be filled with Q-condition pipe - always state it explicitly.
Q4: What is the difference between 3LPE and FBE coating?
3LPE is a three-layer system: FBE primer + copolymer adhesive + extruded polyethylene topcoat, with total thickness typically 1.8–3.7 mm depending on class. It is the standard external coating for buried onshore transmission lines. FBE is a single-layer fusion-bonded epoxy coating, typically 100–150 μm (up to 300–500 μm high-build), used for internal coating, pipe that will receive concrete weight coating, or applications where polyethylene is not suitable. Both are available on X70 LSAW; the choice depends on installation method, soil conditions, and whether concrete coating will be applied.
Q5: Can X70 LSAW pipe be used in sour service (H₂S-containing)?
X70 can be used in mild sour service, but it is more restricted than X65. The standard PSL2 sulphur limit of 0.015% is insufficient - sour-service X70 requires ultra-low sulphur ≤ 0.002%, calcium treatment for sulphide inclusion shape control, HIC testing per NACE TM0284, and SSC qualification review. Not all X70 mills have the secondary metallurgy capability to routinely achieve ≤ 0.002% S. For H₂S partial pressure above 0.05 psia, X65 PSL2 is the default recommendation unless X70 is specifically justified by pressure design and the construction spread is X70-WPS qualified.
Q6: What documentation should I require for an export order?
For X70 LSAW export orders, specify EN 10204 3.2 mill certificate (third-party witnessed), 100% UT report for pipe body and weld seam, hydrostatic test chart for each pipe, Charpy impact results at project test temperature, and heat number traceability per MSS SP-25. EN 10204 3.1 is the standard supply level, but for large-diameter high-pressure transmission projects, 3.2 is the practical minimum for third-party inspection acceptance.
Q7: What is the maximum wall thickness available for X70 LSAW?
Standard LSAW supply ranges extend to 50 mm wall thickness for X70. Commercial mills routinely produce 36″–48″ OD X70 LSAW in 14–32 mm wall, and heavier walls to 50 mm are available for high-pressure or special project requirements. Very heavy wall (> 40 mm) should be confirmed at inquiry stage because plate availability and mill rolling schedules affect lead time.
Our address
Rm1406,14th/F No 208, Hongqi Road, Nankai Dist, Tianjin City ,China
Phone Number(whatsApp/Wechat)
+8616622033809
alisa@tjshenzhoutong.com

Hot Tags: api 5l x70 psl2 lsaw pipe 3lpe coated, China api 5l x70 psl2 lsaw pipe 3lpe coated manufacturers, suppliers, factory, gb standard steel pipe, low alloy steel pipe, low temperature pipe, lsaw pipe, steel tube for column, steel tube for reusable design


